2014年6月16日星期一

The tilt powered pallet truck wall and seals for excessive wear




piled high door frame automatically tilt difficulties or action not smooth
Cause: The tilt cylinder wall and seals for excessive wear; within the valve stem spring failure; piston rod hand pallet jacks in the cylinder wall or bent; within the tilt cylinder seals fouling too much or too compressed.
Solution: Replace the O-rings or cylinders; replace qualified spring; replace damaged parts; cleaning adjustments.
The pump cover seal tank damage, excessive leakage; gear wear; pump motor speed is reduced; pipeline have blockage.

Solution: Replace; replace the oil pump; checking commutator, remove inter-chip coke, carbon brushes to adjust semi electric stacker the position; inspection cleaning.
the operation is not abnormal electrical
Cause: electrical box micro switch is damaged or improperly position adjustment; main electrical control circuit fuse or blown fuse; battery voltage is too low; contactor singeing, or dirt caused by too much bad; contacts without action.
Solution: Replace the micro switch, re-adjust the position; replacement fuse of the same type; recharged; repair contacts, adjust or replace the contactor; checking whether the contactor coil circuit breaker or replace the contactor.

没有评论:

发表评论